Africa Minigrids Program
Nigeria Banner

Documentation: meters_ts

Cette table est obsolète et ne doit pas être utilisée pour les importations de données.

Time Series data of individual meters
Pour importer des données dans ce format, vous pouvez utiliser notre API. -> Documentation de l'API
Rate limit: 300 requests per minute. Once the limit is exceeded, any further requests will result in a 429 (Too Many Requests) response.
Vous pouvez également nous fournir des fichiers au format xlsx, csv ou json. -> Exemple CSV
Nom de la ligne Type Mappage Exemple

manufacturer *

Manufacturer of the device

  • * requis
string installations_ts => manufacturer

A2EI

serial_number *

Serial of the device

  • * requis
string installations_ts => serial_number

ABC/123

metered_at *

time the metrics apply to (not time of query)

  • * requis
datetime installations_ts => metered_at

2021-05-03 6:23:55

data_origin

Origin of the data, generic or name of the api

  • Généré automatiquement
string

generic

custom

Saves additional imported data out of standard structure

  • Généré automatiquement
jsonb

{ "some": "key" }

organization_id

References Organization of data

  • Généré automatiquement
integer

1

import_id

References Import of data

  • Généré automatiquement
integer

1

source_id

References Source of data

  • Généré automatiquement
integer

1

updated_at

Timestamp when row was updated

  • Généré automatiquement
datetime

2021-05-03 6:23:55

created_at

Timestamp when row was inserted

  • Généré automatiquement
datetime

2021-05-03 6:23:55

billing_cycle_start_at

timestamp on which the tariff cycle starts

datetime installations_ts => custom

2021-04-05

interval_seconds

for remotely monitored systems, interval between measurements

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

integer installations_ts => interval_seconds

360

current_a

current in ampere

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_current_a

22.61

frequency_hz

frequency in hertz

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_frequency_hz

58.93

energy_interval_wh

energy consumption at time interval in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_energy_interval_wh

51.04

energy_lifetime_wh

cumulative energy reading in watt-hour

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_energy_cumulative_wh

12473.02

power_w

power in watts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_power_w

1489.6

power_factor

ratio of working power to the apparent power, value between from 0 and 1

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => custom

0.45

voltage_v

voltage in volts

Only period (.) decimal delimiters are supported. Do not use commas (,) — they will cause an error.

float installations_ts => output_voltage_v

164.65

phase

Specifies the phase used for reporting ac_input_* metric values. For one-phase metering, the value is 1, or None. For multi-phase, it is 1, 2, 3 (phase reported) or "agg" (aggregate of all phases)

enum: 1, 2, 3, agg installations_ts => ac_input_phase

2

device_uid

organization_id + manufacturer + serial_number; FK from meters table

  • Généré automatiquement
string installations_ts => device_uid

1_a2ei_ABC123